EasySync USB2-F-7101 Guida Utente Pagina 16

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 45
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 15
Document Reference No.: ES_000005
USB2-F-7x01 Full-Speed USB to 1-Port CANbus Adapter User Guide
Version 1.32
Clearance No.: ES#02
©2008 - 2011 EasySYNC Ltd. 16
4.1.1 Set CAN Channel Timing simple (S)
Summary
Configure CAN interface with a pre-configured channel transmission rate.
NOTE: The CAN channel will revert to its prior state after execution. For example if the channel
is Open when this command is executed, the channel will update the setting and return to the
Open state.
Definition
Srate_selector<CR>
Parameters
rate_selector = 0 = 10Kbps
1 = 20Kbps
2 = 50Kbps
3 = 100Kbps
4 = 125Kbps
5 = 250Kbps
6 = 500Kbps
7 = 800Kbps
8 = 1Mbps
Remarks
Example:
S5<CR>
Set CAN transmission rate to 250Kbps
Return Codes
<CR> = OK
<BELL> = ERROR